16-26KW A+++ DC Inverter Monoblock Air Source Heat Pump for Hot Water Home Heating Cooling

1. Max. COP: 5.60/5.49/5.65/5.53

2. Power Supply: 220V~240V/50Hz/1ph or 380V~420V/50Hz/3ph

3. Running Temp: -20℃~45℃

4. Max. Heating Capacity: 16.5-18.6KW/26 KW

5. Max. Cooling Capacity: 14.7-16.6KW/23.2KW

6. Multi-functions: Hot Water/House Heating/House Cooling
Quantity:
  • CGK050V2; CGK060V2; CGK-080V2

  • SPRSUN

Product-Description
 

SPRSUN’s air to water heat pumps can be an excellent solution to distribute heat and hot water in your house, which has little impact on the environment. This SPRSUN DC Inverter Air Source Heat Pump features ERP A+++ energy level, increasing efficiency and savings effectively. It has a maximum heating capacity of 16.5-26KW, a maximum cooling capacity of 14.7-23.2KW and a maximum COP of 5.65. 
As a renewable and clean solution, SPRSUN’s Monobloc DC Inverter Air to Water Heat Pump can effectively reduce the energy consumption of a residential property and minimize the CO2 emissions to the environment. It runs well at the temperature of -20℃~45℃. 
Its five changeable working modes suit all kinds of needs, including Central Hot Water, Central Cooling, Whole House Heating, Hot Water + House Cooling and Hot Water + House Heating. By using this renewable device, you will eventually pay less in your bills.

 

ERP A+++ DC Inverter Heat Pump


Technical Specifications

 

Model
CGK050V2 CGK-050V2 CGK060V2 CGK-060V2 CGK-080V2 CGK-100V2
Power Supply / Refrigerant V/Hz/Ph 220-240/50/1 - R410A 380-420/50/3 - R410A 220-240/50/1 - R410A 380-420/50/3 - R410A 380-420/50/3 - R410A 380-420/50/3 - R410A
Max. Heating Capacity (1) kW 16.5 16.6 18.5 18.6 26 32
C.O.P (1) W/W 4.48 4.52 4.39 4.42 4.52 4.42
Heating Capacity Min./Max.(1) kW 7.59 / 16.5 7.636 / 16.6 8.51 / 18.5 8.556 / 18.6 11.96 / 26 14.72 / 32
Heating Power Input Min./Max.(1) W 1355 / 3683 1352 / 3673 1551 / 4214 1549 / 4208 2117 / 5752 2664 / 7240
C.O.P Min./Max. (1) W/W 4.48 / 5.6 4.52 / 5.65 4.39 / 5.49 4.42 / 5.53 4.52 / 5.65 4.42 / 5.53
Max. Heating Capacity (2) kW 15.5 15.6 17.4 17.5 24.4 30.1
C.O.P (2) W/W 3.58 3.62 3.4 3.43 3.62 3.43
Heating Capacity Min./Max.(2) kW 7.13 / 15.51 7.18 / 15.6 8 / 17.39 8.04 / 17.48 11.24 / 24.44 13.84 / 30.08
Heating power input Min./Max.(2) W 1676 / 4328 1672 / 4315 1918 / 4952 1915 / 4945 2618 / 6759 3295 / 8507
C.O.P Min./Max. (2) W/W 3.58 / 4.26 3.62 / 4.29 3.51 / 4.17 3.54 / 4.2 3.62 / 4.29 3.54 / 4.2
Max. Cooling Capacity (3) kW 14.7 14.8 16.5 16.6 23.2 28.6
E.E.R (3) W/W 3.48 3.51 3.3 3.32 3.51 3.32
Cooling Capacity Min./Max.(3) kW 6.78 / 14.73 6.82 / 14.82 7.6 / 16.52 7.64 / 16.61 10.68 / 23.22 13.14 / 28.58
Cooling Power Input Min./Max.(3) W 1625 / 4953 1620 / 4939 1859 / 5667 1857 / 5659 2538 / 7736 3194 / 9737
E.E.R Min./Max. (3) W/W 2.97 / 4.17 3 / 4.21 2.91 / 4.09 2.93 / 4.12 3 / 4.21 2.93 / 4.12
Max. Cooling Capacity (4) kW 11.6 11.7 13 13.1 18.33 22.6
E.E.R (4) W/W 2.61 2.63 2.48 2.49 2.63 2.49
Cooling Capacity Min./Max.(4) kW 5.35 / 11.63 5.38 / 11.7 6 / 13.04 6.03 / 13.11 8.43 / 18.33 10.38 / 22.56
Cooling Power Input Min./Max.(4) W 1458 / 4601 1454 / 4587 1668 / 5264 1666 / 5256 2277 / 7185 2866 / 9043
E.E.R Min./Max. (4) W/W 2.53 / 3.67 2.55 / 3.7 2.48 / 3.6 2.49 / 3.62 2.55 / 3.7 2.49 / 3.62
Rated Current  A 17.6 7.8 20.2 8.9 12.1 15.3
Max Current A 25.55 11.24 29.24 12.88 17.6 22.15
Compressor Type - Quantity/System
Twin Rotary - 1
Fan Quantity
2 2


2 2 1
Airflow m3/h 5000 5000


5500 7500 10000
Rated power W 200 200


210 250 500
Water Side Heat Exchanger Type
Plate Heat Exchanger
Water Pressure Drop kPa 23 23


25 23 25
Piping Connection Inch G1" G1"


G1" G1" G1 1/4"
Allowable Water Flow Min./Rated./Max. L/S 0.49 0.79 1.31 0.5 0.79 1.32


0.56 0.89 1.48 0.78 1.24 2.07 0.96 1.53 2.55
Noise Level
dB(A) 62 62


63 62 63
Net Dimension(L×D×H) mm 1100*490*1350 1100*490*1350


1100*490*1350 1237*480*1410 1000*1000*1855
Net Weight Kg 124 124


124 200 300
Note:  (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃;
           (2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃;
           (3) Cooling condition: water inlet/outlet temperature: 23℃/18℃, Ambient temperature: DB35℃/WB24℃;
           (4) Cooling condition: water inlet/outlet temperature: 12℃/7℃, Ambient temperature: DB35℃/WB24℃.
 
The information in this document is just for reference. Since the continuous improvement and control in the production process, the information contained in this document may be subject to change. Please refer to the nameplate on the machine for model specifications.
 



ERP A+++ Energy Label

 

The ERP energy label gives an indication of energy efficiency in products. A rating system of A to G is used to rate the efficiency of products such as heat pumps. The ERP A+++ energy label, rated by TUV SUD, is the highest rating available. This rating indicates that The new DC inverter heat pumps from SPRSUN have been rated ERP A+++ our air source heat pumps have low energy consumption and a high coefficient with a maximum COP of 5.65 and SCOP of 4 88.of performance (COP). The highly energy-efficient DC inverter heat pumps use more than 30% less energy than other air source heat pumps. 

Heat Pump COP

 

Fast Heating Speed

 

Before the indoor temperature reaches the set value, the Panasonic rotary compressor delivers high levels of efficiency, enabling the unit to operate at high frequency so that it can heat water or provide house heating/cooling at a faster speed.

Fast Heating Curve DC Inverter Heat Pumps

 

Smart Control

 

The intelligent CAREL controller with RS485 is adopted to realize the linkage control between the heat pump unit and the terminal application end. With the Cascade function, multiple heat pumps can be controlled at once for greater operating efficiency. The WIFI APP enables users to operate their units through a smart phone wherever and whenever they are.

Smart Control DC Inverter Heat Pump

 

Super Low Noise

 

With Panasonic rotary compressor and DC inverter brushless fans, our DC inverter heat pumps adopt new noise reduction measures so that the sound of the unit is controlled at a satisfactory level. SPRSUN Full Inverter Heat Pump Series can realize low noise running of 59dB(A) when testing at sound power, equivalent to 45dB when testing at 1 meter.

Super Low Noise DC Inverter Heat Pumps

 

Five Working Modes

 

Mode 1 Central Hot Water: Constant Temperature, Sufficient Water Volume, 24-hour Instant Supply 

Mode 2 Central Cooling: Water Cooled Air Conditioning, Soft Air Supply, Comfortable for Human Body. 

Mode 3 Whole House Heating: Water Cycled Floor Heating, Well-distributed Heat Dissipation, Healthy & Energy Saving. 

Mode 4 Hot Water + House Cooling: Meet the Requirements of Both Central Hot Water and Air Conditioning. 

Mode 5 Hot Water + House Heating: Meet the Requirements of Both Central Hot Water and Room Heating.

Five Working Modes DC Inverter Heat Pumps

 

 

Key Components

This Monobloc DC Inverter heat pump comes with components to ensure it works well, including a compressor, an expansion valve, a DC fan, a controller and pressure sensors.

组 21

 

 

Technical Support

 

Our experienced engineering team provides good support for any questions concerning the products and installation before, during and after products are sold. 

 

Before Selling

  • Set up customers file and arrange professional sales engineers to introduce company products and services to customers in details.

  • If customers are interested in our products, we will send professional technicians to survey the installation environment.

  • Provide solutions according to different customers' requirements.

 

 

 

During Selling

  • Machine installed and tested by QA engineers.

  • Ensure all the products we provide are qualified and new. The working life of the main engine is 15 years.

  • Construct and install the heat pump according to national relevant policies strictly and ensure high quality delivery on time.

  • Test and debug the equipments strictly to ensure the safety and stability.

  • During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers.

 

 

 

After Selling

  • We promise to offer free consulting call in 7×24 hours mode to solve the problems found in practice. The number is 86-20-82181867.

  • Sprsun offers standard 24-month warranty. Customers can choose to extend the warranty to 5 years with a small amount of fee. Within the warranty period since the delivery date, if the product has any failure under normal usage, Sprsun will provide free assembly parts. 

  • After the expiration of the warranty period, we will continue to provide lifelong maintenance services, with just a small amount of charges.

 

 

Previous: 
Next: 
Contact Us

Guangzhou SPRSUN New Energy Technology Development Co., Ltd.

A Professional Heat Pump Manufacturer Since 1999
No.15 Tangxi Road, Yinsha lndustrial Park, Xintang, Zengcheng , Guangzhou, Guangdong, China, 511338

Contact SPRSUN. 7/24 Support. We Will Reply You ASAP!

Tel: 0086-20-82181867
Phone: 0086-18933985692