Professional heat pump manufacturer since 1999
Message To
inquiry@sprsun.com
Skype
sprsun.sprsun
Quick Contact
0086-20-82181867
You are here: Home » Products » DC Inverter Air Source Heat Pumps » 9.5KW A+++ Energy Label DC Inverter Air to Water Heat Pump - Monoblock Type
PRODUCTS
Share to:

9.5KW A+++ Energy Label DC Inverter Air to Water Heat Pump - Monoblock Type

1. Max. COP: 5.56

2. Power Supply: 220V~240V/50Hz/1ph

3. Running Temp: -20℃~45℃

4. Max. Heating Capacity: 9.5KW

5. Max. Cooling Capacity: 8.5KW

6. Multi-functions: Hot Water/House Heating/House Cooling

Quantity:
  • CGK030V2
  • SPRSUN

Heat Pump Features

A+++ Energy Label DC Inverter Heat Pump


With 24-month long warranty, SPRSUN Monoblock DC Inverter Air Source Heat Pumps are designed for domestic hot water, room heating and cooling with lowest ambient temperature -20℃. They are featured with: 


  • Higher Energy Efficiency

Achieving the ERP A+++ energy class, our DC inverter heat pumps save energy by more than 30% compared with other ordinary air source heat pumps. 


  • Smart Control

The intelligent CAREL controller with RS485 WIFI APP is adopted to realize the linkage control between the heat pump unit and the terminal application end. With the Cascade function, multiple units can be controlled with one panel. 


  • Reduced Defrosting Time

The smart defrosting technology is able to avoid defrosting when there is no frost. 


  • Panasonic Rotary Compressor 

Stable operation ensures low noise and high efficiency. No need for external power supply, which reduces energy loss and ensures high efficiency. 


  • Wide Voltage Application

The DC Inverter Air Source Heat Pumps operate normally within the voltage range of 176V-245V to reduce the impact of voltage instability on the environment.

DCInverterCOP

3PDCInverterHeatPumpsA

CAREL Controller


Heat Pump Specifications

Model
CGK030V2
Power Supply / Refrigerant V/Hz/Ph 220-240/50/1 - R410A
Max. Heating Capacity (1) kW 9.5
C.O.P (1) W/W 4.45
Heating Capacity Min./Max.(1) kW 4.37 / 9.5
Heating Power Input Min./Max.(1) W 786 / 2135
C.O.P Min./Max. (1) W/W 4.45 / 5.56
Max. Heating Capacity (2) kW 8.9
C.O.P (2) W/W 3.60
Heating Capacity Min./Max.(2) kW 4.11 / 8.93
Heating power input Min./Max.(2) W 972 / 2508
C.O.P Min./Max. (2) W/W 3.56 / 4.23
Max. Cooling Capacity (3) kW 8.5
E.E.R (3) W/W 3.50
Cooling Capacity Min./Max.(3) kW 3.90 / 8.48
Cooling Power Input Min./Max.(3) W 942 / 2871
E.E.R Min./Max. (3) W/W 2.95 / 4.14
Max. Cooling Capacity (4) kW 6.7
E.E.R (4) W/W 2.62
Cooling Capacity Min./Max.(4) kW 3.08 / 6.70
Cooling Power Input Min./Max.(4) W 845 / 2667
E.E.R Min./Max. (4) W/W 2.51 / 3.65
Rated Current  A 10.2
Max Current A 14.81
Compressor Type - Quantity/System
Twin Rotary - 1
Fan Quantity
1
Airflow m3/h 3000
Rated power W 100
Water Side Heat Exchanger Type
Plate Heat Exchanger
Water Pressure Drop kPa 20
Piping Connection Inch G1"
Allowable Water Flow Min./Rated./Max. L/S 0.28 0.45 0.76
Noise Level
dB(A) 59
Net Dimension(L×D×H) mm 1100*490*810
Net Weight Kg 88
Note:  (1) Heating condition: water inlet/outlet temperature: 30℃/35℃, Ambient temperature: DB 7℃/WB 6℃;
        (2) Heating condition: water inlet/outlet temperature: 40℃/45℃, Ambient temperature: DB 7℃/WB 6℃;
      (3) Cooling condition: water inlet/outlet temperature: 23/18, Ambient temperature: DB35/WB24;
    (4) Cooling condition: water inlet/outlet temperature: 12/7, Ambient temperature: DB35/WB24.



Installation Diagram


It is easy to install SPRSUN monoblock type DC inverter air source heat pumps as shown by the following Installation Diagram: 

DCinverterinstallation



Technical Support


Our experienced engineering team provides good support for any questions concerning the products and installation before, during and after products are sold. 


Before Selling

  • Set up customers file and arrange professional sales engineers to introduce company products and services to customers in details.

  • If customers are interested in our products, we will send professional technicians to survey the installation environment.

  • Provide solutions according to different customers' requirements.


During Selling

  • Machine installed and tested by QA engineers.

  • Ensure all the products we provide are qualified and new. The working life of the main engine is 15 years.

  • Construct and install the heat pump according to national relevant policies strictly and ensure high quality delivery on time.

  • Test and debug the equipments strictly to ensure the safety and stability.

  • During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers.


After Selling

  • We promise to offer free consulting call in 7×24 hours mode to solve the problems found in practice. The number is 86-20-82181867.

  • SPRSUN offers 24-month long warranty. Within 24 months since the delivery date, if the product has any failure under normal usage, Sprsun will provide free assembly parts.

  • After the expiration of the warranty period, we will continue to provide lifelong maintenance services, with just a small amount of charges.



PROJECTS WORLDWIDE

Guangzhou Sprsun New Energy Technology Development Co., Ltd

 Add: No.15 Tangxi Road, Yinsha Industrial Park, Xintang, Zengcheng District, Guangzhou,511338, China
 E-mail: inquiry@sprsun.com
 Tel: 0086-20-82181867
 Phone: 0086-18933985223
 Skype: sprsun.sprsun
Want to Buy Heat Pumps? Contact Us Now!

CONTACT US
2020 SPRSUN Heat Pump Factory Live Demo Invitation
DC Inverter Air to Water Heat Pumps
Copyright  Guangzhou Sprsun New Energy Technology Development Co., Ltd. All rights reserved.